This is Styra 3000

A flexible control unit that manages all the property’s needs including entry phones, booking and access systems, door units and alarms. The Styra 3000 has smart features including language support for the entry phone Ringa and booking board Boka and control of laundry equipment.

The easy-to-install control unit

Organize the cards and cables in your control unit. Colormarked terminal blocks match stripped Aptus cables. Userfriendly lock with a closing mechanism and a special hinge that allows you to prop the lid open or unhook it.

A man standing in an hallway.A man standing in an hallway.

Easy cable installation

Instead of running the cable from the control unit to all products at the door, simply run the Aptus 485 bus from the control unit to the door unit. Then connect the door environment and its related products (e.g. readers, entry phones, locks) to the Koppla door unit. s Koppla 4300 has four double balanced inputs and three outputs. Koppla 2100 is a door unit for basic doors, with two inputs and one output. Both door units can activate locks and detect if a door is open. Both units have a tamper switch and a buzzer with various programming options.

The reliable control unit

Operational reliability and easy reader replacement. Sepa - rate fuses, bus cables and compartmentation enhance this control unit's operational reliability. These features ensure that the control unit continues working if part of the system fails. For instance, if the the entry door is damaged, the ba - sement and laundry room doors will remain unaffected. The buses and outlets have electronic fuses, which protects both the buses and outputs in the event of short circuiting. The advantage of having fused outputs is that they remain undamaged in the event of short circuiting. This makes it easy to fix damaged cables, strike plates etc. and get the output working again.

The versatile control unit

You decide which Styra 3000 unit in your system will be assigned master or slave status and which functions it will have. Internal and external inputs and outputs can be freely combined. If you want to expand the system with new functions, just add the chosen function via an expansion card or an additional control unit. It can also control other functions such as lighting and alarms.

  • Internt tillbehör

    Styra Komkort 4000

    Kommunikationskort som erbjuder fyra avsäkrade och skyddade A485-portar
    (max två per central).

  • Internt tillbehör

    Styra I/O 8800 // Styra I/O 4400

    Kort med åtta ingångar och åtta utgångar alternativt fyra ingångar och fyra utgångar. (max två per central).

  • Internt tillbehör

    Styra Porttelefonkort 4400

    Kommunikationskort med stöd att ansluta porttelefoner (Ringa) till fyra dörrar. (max ett per central).

  • Internt tillbehör

    Styra Porttelefonkort 4800

    Kommunikationskort med stöd att ansluta porttelefoner (Ringa) till ytterligare fyra dörrar, dörr fem - åtta. Obs! Kortet kräver att Styra Porttelefonkort 4400 också finns installerat i centralen. (max ett per central).

  • Externt tillbehör

    Dörrenheter, I/O-enheter, läsare, porttelefoner, bokningstavlor, lås, temperaturgivare, el- vatten- och energimätare, namntavlor, larmpaket, fastighetsboxstyrning och förrådslås.

Product highlights

  • Master key systems

    With over 70 years' experience of designing and supplying cylinders and keys throughout the world, ASSA is established as the first choice for high security, robust and sophisticated master key systems. 
  • ASSA lock spray

    Article number: 807718100000 ASSA Lock Spray is a lubricant. Use it to significantly enhance the reliability and longevity of mechanical and electromechanical cylinders. Features EFFECTIVE – small dosage gives quick results RAPID DRYING – does not bind dust and grit WATER RESISTANT – does not bind salt, protects against corrosion SERVICE AND MAINTENANCE – recommended twice a year or according to the building’s service schedule ANTI FREEZE – De-Icing and anti-freezing properties Cleaning instructions Shake before using. Insert the spray nozzle into the keyway of the cylinder and press the button for one second. Remove the nozzle from the keyway, insert the key and turn a couple of times. Wipe the key clean of any excess lubricant. Service and maintenance Several factors can affect the opening and closing of a door. To ensure the best functionality and durability, all doors require regular service and preventive maintenance. Lock cylinder and keys Service and maintenance is recommended twice a year or according to the building´s service schedule. Always use ASSA Lock Spray A conventional lockspray may clog a mechanical cylinder and damage an electromechanical cylinder. For locks in frequently used doors or locks exposed to harsh environmental conditions we recommend more frequent lubrication. To avoid any disruptions in functionality due to condensation and/or freezing, maintenance should be scheduled before the winter period in cold climates. ASSA electro mechanical functions, such as CLIQ, should be tested in accordance to the buildings maintenance agreement. A yearly test of the electro mechanical functionality is also recommended. The battery capacity of CLIQ keys should be checked once a year. Keys with high usage tend to wear and should be replaced if the user experiences reduced opening functionality of the cylinder. Warning! Never use grease, oil or graphite-based lubricants in locking cylinders, as these lubricants cause disruptions in functionality and clog up the mechanism.
  • Key management & software

    Our specially designed software, with internal security routines, calculates and manages master keyed systems. This guarantees optimal security the calculation and production of the system. The database contains all information pertaining to system. All corrections and changes communicated to ASSA are registered, so we can provide fast and correct information.
  • ASSA Performer

    ASSA Performer is our software for keyadministration. It is also our software for handling the product dp CLIQ.
  • ASSA Performer

    ASSA developed its ASSA Performer software to help system administrators manage the keys in their Master Key Systems. As long as you maintain control of all your keys, your Master Key System will remain secure. If you lose this control, the security can be compromised. There are four questions you must be aware of in key administration: 1. What keys have been distributed? 2. To whom have these keys been distributed? 3. What doors can a key holder access? 4. When are the keys due to be returned? Manual key management is time consuming. It also increases the risk of errors. ASSA Performer gives you enhanced control of your lock system. ASSA Performer is user friendly software withmany functions that will improve the management of your security system – some of the functions include: Managing contacts and addresses Distributing and receiving keys Changing status of keys , for instance if one is reported lost or stolen Ordering keys from your supplier Generating reminders for distribution and return dates and times Search functions Finding out what a specific key goes to Finding out which keys and users have access to a specific cylinder Printing an array of reports Printing receipts for keys that have been distributed or returned ASSA Performer with Outlook connection ASSA Performer with the Outlook add-on, makes it possible to select persons from your Outlook address book and to get reminders in your Outlook Calender.
  • ASSA Security Master

    ASSA Security Master is a professionell tool from ASSA AB, helping you work with your Master Key Systems.
  • Security Master

    ASSA ASSAs emphasis on data communication is embodied in the design, calculation and archive services of our master keyed systems (MKS), as well as our own production management. ASSA Security Master is used for both designing and creating the MKSs. ASSA Security Master also communicates with ASSAs own mainframe. This means that the manufacturing of keys and cylinders is controlled by information from the lock chart. Whether the original design came from ASSA or a security contractor, locking is registered in the mainframe archive database. This lays the foundations for a well-functioning service and ensures ease of future expansions of the system. Input Basic data of the MKS. File with MKS details from security manager, architect, or security consultant. Building drawing. Survey by the ROOT objects. Output Lock chart. Quote. Order Basis. Authorization contract. Fitting Specification. Mounting List. Key and cylinder list. Combination list.