• Voltage
    12Vdc & 24Vdc

    Current
    250 mA @ 12Vdc - 125mA @ 24Vdc

    Solenoid
    Solenoids are rated for continuous use.

    Monitoring
    None

    Holding Force
    680 kg Static Strength Rating

    Endurance
    Cycle tested to 1,000,000 operations

    Environment
    Operational temperature range -20°C to + 60°C
    Weather resistant construction Standard. (IP56)

    Body
    Cast Aluminium Construction

    Keeper
    Stainless Steel

    Latch
    Suitable for 18mm latchbolt with 3mm door gap

    Specification Statement
    Where Power to Lock and Power to Open functions may be required in the same building, the strike must be interchangeable from either "Power to Lock" or "Power to Open" on site. The electric strike should not consume current greater than 250 mA @ 12Vdc - 125mA @ 24Vdc and have a solenoid suitable for continuous use. Certifications must include CE, C-tick and 4hr fire rating. The strike should have a minimum holding force of 680kg, and an endurance rating of 1 million cycles.

     

Contact us