• Voltage
    12Vdc - 24Vdc Operating Voltage.

    Current
    500mA (max) 80mA holding @ 12Vdc.
    275mA (max) 50mA holding @ 24Vdc.

    LED Current
    When LED's are fitted, add 15mA (max) to total current draw.

    Monitoring

    • Dual Key override
    • Deadlatched
    • Locked
    • Door closed
    • Request to exit
    • Microswitches: 500mA (max) @ 30Vdc each circuit.
    • Reedswitch: 100mA (max) @ 30Vdc.

    Environment
    Operational temperature range -20c to + 60c.

    Case / Cover
    High purity Zinc alloy construction.

    Backset
    60mm standard, 89 & 127 mm available.

    Latch bolts
    Reversible with Stainless Steel construction.

    Door Clearance
    3 - 6.5 mm

    Door thickness
    Standard applications 32 to 50mm.

    Cylinder
    Standard Lockwood oval shaped cylinders.

    Cabling
    1.6 metre length of cable with 12 pin socket supplied with each lock.
    Recommended cable: 18AWG (0.82mm²) cable runs up to 30m.

    Furniture
    Compatible with Lockwood series door furniture.

    Standard Finishes
    Satin Chrome (SC) standard. Bright Chrome (CP) and Polished Brass (PB) finishes available.

    Note: For detailed electrical specifications, refer to catalogue.

    Specification Statement
    The lock should be capable of operation on voltages between 12 - 24Vdc and have a current consumption not more than 80mA (holding) @12Vdc and 50mA (holding) @24Vdc.

    Monitored locks must be capable of monitoring the following functions: Key override, door position / reed switch, selectable hub / Request to exit, & locking bar status.

    All monitoring outputs must have the ability to be wired independently.

    All settings - including: fail safe / fail secure, handing, hub selection must be field configurable.

    _________________________________________________________

    Dimensions

Contact us