7 results

  • CLIQ Connect mobile app

    CLIQ Connect mobile app makes updating your CLIQ keys a truly mobile experience. The CLIQ Connect mobile app can be used instead of, or in conjunction with, the CLIQ Connect PC app when updating keys.
  • CLIQ Connect Mobile Programming Device

    CLIQ Connect Mobile Programming Device is a device that is paired with a mobile phone using Bluetooth to form a link between the mobile and the CLIQ key so that the CLIQ key can be updated via the mobile phone.
  • CLIQ Connect PC app

    App used when updating CLIQ keys.
  • CLIQ Web Manager

    CLIQ Web Manager is a full feature web based software for managing your eCLIQ system. CLIQ Web Manager provides easy, secure and flexible management of your eCLIQ keys and cylinders.
  • eCLIQ Connect keys

    Utilises Bluetooth Low Energy technology in the key.
  • CLIQ Go mobile app

    Makes managing your CLIQ Go system a truly mobile experience.
  • CLIQ Go web site

    CLIQ Go web site makes it easy to manage your CLIQ Go system from a PC.
Showing 7 of 7
  • ASSA ABLOY® eCLIQ is suitable for various industries.

    • Schools
    • City Councils
    • Museums
    • Art centres
    • Nursing homes, smaller hospitals and health centres
    • Commercial buildings and factories
    • Transport and logistics
    • Infrastructure
    • Offices
    • An application with a need for electronic access control in remote locations

    Please contact one of our Distributors or ASSA ABLOY direct for more information.

    Environmental restrictions for use

    Use temperature: key 0°C …+70°C
    Use temperature: cylinder -25°C …+85°C

    Dust and water protection

    Cylinder: IP classification IP 54 (=protected against dust and water splashed from all directions).
    IP classification IP 55 (if dust covers are used) (=protected against dust and low pressure jets of water from all directions).
    Padlock: IP classification IP 67 (= No dust can enter the key, and it is protected immersion).
    Key: IP classification IP 67 (= No dust can enter the key, and it is protected immersion).

    Time functions

    eCLIQ keys have a clock and calendar feature.
    An eCLIQ key can be programmed to be: always active, active between certain dates or inactive.
    It is also possible to set a weekly operation schedule to the key. The calendar allows the administrator to specify up to 32 time periods where the key is granted access throughout the week. Cylinder specific time periods can be programmed in the key. The key can for instance be programmed to open all cylinders Mon - Fri 8AM - 5PM except for one (or more) cylinder(s) which can only be opened on Saturdays.

    The clock has an accuracy of minimum +/- 1 minute per month.

    Lifetime of the products

    The expected lifetime of the electronic products is about seven years. After that the failure rate of any electronic products starts to grow due deterioration of electronic components and overall wear.

  • Specification Statement

    The Keying System must use a symmetrical electronic key and electronic cylinder. The battery in the key must power up the cylinder upon key insertion.

    Technical Information

    CLIQ Key Material: The key shaft is made out of stainless steel. The key electronics and the battery are located under a plastic cover.

    Active / Passive Key: Active (electronically)

    Symmetrical / Asymmetrical Key: Symmetrical

    CLIQ Key Indications: The key electronics contains a small buzzer and a LED that provides the key holder with a visual and audible access indication.

    1 short beep and 1 short green light
    The key is granted access

    3 short beeps and 3 short red lights
    No locking permissions or key outside the time zone

    3 short beeps and 3 short red-green-red lights
    Key outside the time zone

    3 long beeps and 3 short green or red lights
    The battery may be low or cold (try warming the key in your hand)

    No beep
    The battery is empty

    CLIQ Key stampings
    The key identification stampings are made on the metal of the key.

    Speed of the electronic function
    CLIQ cylinders can be operated 0.1 seconds after key insertion. An audible and visual indication is given to the key holder when the key can be turned.

  • CLIQ key battery

    The battery powers the electronics in the key as well as in the cylinder.

    The battery is located in the key bow under a plastic cover.

    Battery specifications
    Size ø 20 x 3.2 mm.
    3 V lithium (type CR 2032).
    Lifetime is about three years or 30,000 key operations.

    The battery must be changed when the key starts to indicates a low battery warning. It is possible to make around 200 key operations before the battery is empty once the low battery warnings are given.

  • Aspect

    CLIQ Web ManagerCLIQ Go
    Description and applicationEnterprise full feature software suitable for all types of installations including large onesLightweight software developed for smaller installations that can be managed via a mobile phone app
    User interface -  administrationWebWeb + Android/iOS apps
    Functionality / ease of use
    Powerful but complex, requires trainingSimple and intuitive, limited functionality
    Functionality for large systemsBulk changes, operations on search resultsNot designed for large systems
    AdministrationMultiple adminstrators with configurable permissionsSingle administrator (login password). Can login from several devices though
    User interface - key updatesDesk PD, Wall PD, Mobile PD, Mobile phone app, Bluetooth keysDesk PD, Mobile PD, Mobile phone app, Bluetooth keys
    Data fieldsMultiple data fields for each element (keys, cylinders, people, etc)Only name and marking for keys and cylinders
    PeoplePeople as separate entitity type, hand out of keys to peopleNo concept of people, but keys can be named based on key holder and cylinders based on location
    KeysSupport Dynamic and Normal user keysSupport Dynamic user keys only
    Email notifications to key holdersSupportedNot supported
    C-keys (Admin/programming keys)Supported and requiredN/A
    Time schedules for keysGlobal schedule and schedule for access to specific cylindersOnly global schedule
    Validity of keysStart and end timeStart and end time
    Revalidation of keysSupportedNot supported
    Audit trailsKey and cylinder side audit trail, searchable audit trail archiveOnly cylinder side audit trail
    Cylinder programmingBy C-keysBy user keys
    CSV Import/ExportExport of keys, cylinders and persons, import of data for cylinders and peopleNot supported
    Integration with web servicesSupportedNot supported
    Access profiles (group cylinders)SupportedNot supported
    Domains (split the system between the administrators)SupportedNot supported
    Temporary access groups (planned future authorisations)SupportedNot supported
    Firmware upgradeSupportedNot supported