    Construction:

    • galvanised steel sheet
    • door leaf: sheet thickness 0,8 mm
    • door frame: sheet thickness 1,5 mm

    Design:

    • glass pane, classes EI30, EI60, EI90
    • solid, classes EI30, EI60, EI90

    TYPE DESIGNATIONS

    EI30 glass pane PV-2/30-S-M solid PV-2/30-M

    EI60 glass pane PV-2/60-S-M solid PV-2/60-M

    EI90 glass pane PV-2/90-S-M solid PV-2/90-M

    Finishing options:

    • galvanised
    • plasticised in RAL colours
    • veneered door leaf, plasticised door frame

    Gaskets:

    • in door frame (three-sided); rubber – self-extinguishing; black expanded, black
    • in floor
    • without gasket (standard), only fire door
    • with gasket – drop down seals or threshold; fire / smoke / soundproof

    Fittings:

    • fire door lock EN 12209 (standard or panic function)
    • 3D inox hinges
    • fire door handle with round rosette (black PVC or stainless steel)
    • hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

    Installation: dry installation – door frame and wall joint with finish profile

    Leaf thickness: 62 mm

    Leaf weight:

    EI30 approx 40 kg/m2

    EI60 approx 45 kg/m2

    EI90 approx 60 kg/m2

    The doors are certified 15 by a certified institution as a standard product under an applicable standard, complete classification (according to EN 1634-1)