Construction:
- galvanised steel sheet
- door leaf: sheet thickness 0,8 mm
- door frame: sheet thickness 1,5 mm
Design:
- glass pane, classes EI30, EI60, EI90
- solid, classes EI30, EI60, EI90
TYPE DESIGNATIONS
EI30 glass pane PV-2/30-S-M solid PV-2/30-M
EI60 glass pane PV-2/60-S-M solid PV-2/60-M
EI90 glass pane PV-2/90-S-M solid PV-2/90-M
Finishing options:
- galvanised
- plasticised in RAL colours
- veneered door leaf, plasticised door frame
Gaskets:
- in door frame (three-sided); rubber – self-extinguishing; black expanded, black
- in floor
- without gasket (standard), only fire door
- with gasket – drop down seals or threshold; fire / smoke / soundproof
Fittings:
- fire door lock EN 12209 (standard or panic function)
- 3D inox hinges
- fire door handle with round rosette (black PVC or stainless steel)
- hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)
Installation: dry installation – door frame and wall joint with finish profile
Leaf thickness: 62 mm
Leaf weight:
EI30 approx 40 kg/m2
EI60 approx 45 kg/m2
EI90 approx 60 kg/m2
The doors are certified 15 by a certified institution as a standard product under an applicable standard, complete classification (according to EN 1634-1)