• Construction:

    • galvanised steel sheet
    • door leaf: sheet thickness 0,8 mm
    • door jamb: sheet thickness 1,5 mm

    Design:

    • glass pane, classes EI30, EI60, EI90
    • solid, classes EI30, EI60, EI90 and EI120

    TYPE DESIGNATIONS

    EI30 glass pane PV-1/30-S solid PV-1/30

    EI60 glass pane PV-1/60-S solid PV-1/60

    EI90 glass pane PV-1/90-S solid PV-1/90

    EI120 solid PV-1/120

    Finishing options:

    • galvanised
    • plasticised in RAL colours
    • veneered door leaf, plasticised door frame

    Gaskets:

    • in door frame (three-sided) rubber – self-extinguishing, black expanded, black
    • in floor • without gasket (standard), only fire door
    • with gasket – drop down seals or threshold, fire / smoke / soundproof

    Fittings:

    • fire door lock EN 12209 (standard or panic function)
    • 3D inox hinges • fire door handle with round rosette (black PVC or stainless steel)
    • cylinder with three keys (standard or with button)
    • cylinder and handle rosette are round, separated
    • hydraulic door closer for fire door EN 1154 with guide rail (standard RAL 9006)

    Installation: dry installation – door frame and wall joint with finish profile

    Leaf thickness: 62 mm

    Leaf weight:

    EI30 approx 40 kg/m2

    EI60 approx 45 kg/m2

    EI90 approx 60 kg/m2

    EI120 approx 75 kg/m2

    Single-leaf steel fire doors may also be available in smokeproof design – with EN 1634-3 certificate.