Construction:
- fire insulation lining
- finish lining - standard aluminium profiles TM 75 and TM 90
Design: fire resistance classes EI30, EI60 and EI90
Type designations: EI30 EI60 EI90
Glass pane PV-1/30-Y PV-1/60-Y PV-1/90-Y
Glass pane PV-2/30-Y PV-2/60-Y PV-2/90-Y
Glass pane PS-30-Y PS-60-Y PS-90-Y
Finishing: plasticised in RAL colours or
Gaskets:
- in door frame (three-sided) rubber – self-extinguishing, black expanded, black
- in floor
- without gasket (standard), or
- with gasket – drop down seals or threshold
Fittings:
- fire door lock EN 12209 (central)
- 3d adjustable hinge (2 pcs)
- fire door handle with oval rosette EN 1906 – stainless steel
- rosette for cylinder and handle, oval, separated – stainless steel
- cylinder with three keys (standard or with wheel)
- hydraulic door closer for fire door EN 1154
Glazing:
- glazing with fire resistant glass, classes EI30, EI60 and EI90
- maximum glass pane dimensions 1070 x 2370 mm
Installation:
- on finished wall
- on unfinished wall – installation of door buck, wall finishing before door installation
Single-leaf steel fire doors may also be available in smokeproof design – with EN 1634-3 certificate.
The doors are certified by a certified institution as a standard product under an applicable standard, complete classification (according to EN 1634-1 and EN 16034)