• Voltage: 11.4 - 26VDC
    • Current: Peak Current: 1000mA, Idle Current: 35mA @12VDC with LED activated
    • Unlocking Pre-Load: Side Load rated: Motorised unlocking - 100kg max at the bolt
    • Strength: Maximum 1000kg
    • Monitoring: Lock Status Monitoring: NO/NC, Door Position Monitoring: NC
    • Unlocking Time: 1 Second under Preload
    • Locking Time: 3 Seconds
    • Environment: Weather resistant construction to IP53
    • Operating Temperature:  -10 to +60 Degrees Celsius
    • Endurance: 500,000 operations (120N Unlocking, 50N Locking)
    • Dimensions: Body: 210L x 24W x 42D (mm), Faceplate: 256L x 30W (mm), Strike Plate: 256L x 30W (mm)
    • Construction: Stainless Steel lock body, Face plate and Strike Plate

    Standards and Compliance

    • Regulatory Compliance Mark (RCM) for Australia and New Zealand
    • CE & UKCA certified for Europe under EN 14846 for the Construction Product Regulations (CPR)
    • CE & UKCA compliance for Europe (EMC, RoHS, WEEE, REACH)
    • FCC compliance (EMC, TSCA and Prop65)
    • Fire rated up to 240 minutes (EU/UK/AU)
    • Successfully fire rated up to 4hrs on fire door assemblies in accordance with BS/EN 1634-1 & AS1905.1 (Part 1: Fire resistant door sets)
      For any fire rated applications of this product, the fire certification should be investigated and examined to ensure the suitability & configuration of this product for that particular door assembly. Contact the supplier for further details, such as certifications, door type and door thickness etc. that may affect the fire door suitability and rating.
    • S8 (Security Australian Lock Standard (AS4145.2.2008)
    • D8 (Durability) Australian Lock Standard (AS4145.2.2008)
    • IP53 Rating

    Specification Statement:

    The lock must be a high torque motorised bolt with pre-load tolerance, capable of unlocking with up to 100kg of side pressure (Pre-Load) and Locking up to 35kg Pre-Load. The lock must have a minimum IP Rating of IP53, include integrated lock status and diagnostics LED indication, lock status and door position monitoring and be site configurable for Fail Safe (PTL) or Fail Secure (PTO) operation. The lock shall accept an operating voltage between 11.4 to 26VDC and draw no more than 1000mA during change of state and 35mA when idle.

    The strike plate must be shaped in a V format to accommodate up to 12mm (total) for misaligned doors. The lock must be triggered with a magnet positioned in the strike plate and be monitored for locked, unlocked and door position.

    Dimensions

     

  • DescriptionPart numberBar code
    ASSA ABLOY ES8100 V-Lock, 11.4 -26VDC, Fail Safe, Full MonitoringES81009348313051267
    ES8100 V-Lock Glass Door Housing (Includes Dress Plate & Fixing Tape)208000-0009311847929074
    ES8100 V-Lock Strike Plate with Magnet208100-0039348313051328
    ES8100 V-Lock Retrofit Strike Plate with Magnet, used when replacing an ES8000 (Reduce door misalignment from 12mm to 7mm)208100-0049340116140100
    ES8100 V-Lock replacement connection lead208100-0109348313052608

New and improved ASSA ABLOY ES8100 V-Lock

2-Wire vs 3-Wire configuration

Advantages of configuring ES8100 V-Lock for 3-wire operation

0:00 / 0:00

Product Certification

Request Product Compliance Documents including Declarations of Conformance (DoC), Fire Certificates and more.

product certificationproduct certification

Cable Calculator

Contact us

Victoria – Head Office

Incedo Hardware
+8
PadlocksASSA ABLOY eCLIQ TechnologyAperio® TechnologyDigital Cam Locks
Integral Wireless Access ControlElectromechanical LockingEgress Buttons and ActuatorsSMARTair